6–in–1 ÇϳªÀÇ °í¼º´É ¿À½Ç·Î½ºÄÚÇÁ¿¡¼
½ÅÁ¦Ç° MDO4000C È¥ÇÕ µµ¸ÞÀÎ ¿À½Ç·Î½ºÄÚÇÁ
NEW MDO4000C Mixed Domain Oscilloscope
MDO4000C ¿À½Ç·Î½ºÄÚÇÁ´Â °·ÂÇÑ Æ®¸®°Å¸µ, °Ë»ö ¹× ÆÄÇü ºÐ¼®À» °¡´ÉÇÏ°Ô ÇÏ´Â ±ä ¸Þ¸ð¸®¸¦ Á¦°øÇÕ´Ï´Ù. ÃÖ´ë 6°³ÀÇ ³»Àå Àåºñ¸¦ Ãß°¡ÇÒ ¼ö ÀÖÀ¸¸ç, °¢ Àåºñ´Â ±î´Ù·Î¿î ¹®Á¦¸¦ ÇØ°áÇÒ ¼ö ÀÖ´Â ¶Ù¾î³ ¼º´ÉÀ» Á¦°øÇÕ´Ï´Ù.
¾Æ³¯·Î±×, µðÁöÅÐ ¹× RFÀÇ °íÀ¯ÇÏ°í µ¿±âÈµÈ º¸±â¸¦ À§ÇØ ½ºÆåÆ®·³, ·ÎÁ÷ ¹× ÇÁ·ÎÅäÄÝ ºÐ¼®À» °áÇÕÇÕ´Ï´Ù. ¹«¼± ¸ðµâ ÅëÇÕ ¶Ç´Â EMI ¹®Á¦ ÇØ°á°ú °ü·ÃµÈ ¾î·Á¿òÀÌ ÀÖ´Ù¸é ÀÌ ½ºÄÚÇÁ°¡ °¡Àå ÀûÇÕÇÕ´Ï´Ù.
Ư¡ | ÀåÁ¡ |
20M Æ÷ÀÎÆ® ·¹ÄÚµå ±æÀÌ | ´õ ¿À·£ ½Ã°£ µ¿¾È ¼¼¹ÐÇÑ ½ÅÈ£ Á¤º¸¸¦ È®´ëÇÏ¿© ºÐÇØ´ÉÀ» À¯ÁöÇÒ ¼ö ÀÖ½À´Ï´Ù. |
Wave Inspector? Ž»ö | Á÷°üÀûÀÎ Àü¸é ÄÁÆ®·ÑÀ» »ç¿ëÇØ ¿øÇÏ´Â ½ÅÈ£¸¦ ½±°Ô Ž»öÇÕ´Ï´Ù. ¹ß»ýÇÑ ¸ðµç À̺¥Æ®¸¦ ÀÚµ¿À¸·Î ã¾Æ Ç¥½ÃÇÕ´Ï´Ù. |
FastAcq °í¼Ó ÆÄÇü ĸó | ÃÊ´ç 340,000°³ ÀÌ»óÀÇ ÆÄÇüÀ» ÅëÇØ ¹®Á¦¿Í ±âŸ ºñÁ¤»óÀûÀÎ °úµµ ½ÅÈ£¸¦ ºü¸£°Ô ½Äº°ÇÕ´Ï´Ù. Ä÷¯ ±×·¹À̵ùÀ» »ç¿ëÇØ °ü½É ÀÖ´Â À̺¥Æ®¸¦ ½±°Ô ÆľÇÇÕ´Ï´Ù. |
¾Æ³¯·Î±× ä³Î 4°³ – µðÁöÅРä³Î 16°³ ¹× RF ä³Î 1°³(¿É¼Ç) | ¾Æ³¯·Î±×, µðÁöÅÐ ¹× RF ½ÅÈ£ ºÐ¼®À» ½Ã°£ µ¿±âÈÇØ ½Ã½ºÅÛ ·¹º§ ¹®Á¦¸¦ ¼Õ½±°Ô ÇØ°áÇÕ´Ï´Ù. ¸ðµç ä³Î¿¡¼ Æ®¸®°ÅµË´Ï´Ù. |
³ÐÀº ´ë¿ªÆøÀ» °®Ãá ÅëÇÕ ½ºÆåÆ®·³ ºÐ¼®±â | -65dBc (ÀϹÝ) µ¿Àû ¹üÀ§¿Í 6GHz ÁÖÆļö ¹üÀ§·Î RF ½ÅÈ£¸¦ Á¤È®È÷ ºÐ¼®ÇÕ´Ï´Ù. ÃÖ´ë 3.75GHzÀÇ ¸Å¿ì ³ÐÀº ĸó ´ë¿ªÆøÀ» ÅëÇØ Àüü ½ºÆåÆ®·³À» µ¿½Ã¿¡ º¼ ¼ö ÀÖ½À´Ï´Ù. |
ÅëÇÕ ÀÓÀÇ/ÇÔ¼ö ¹ß»ý±â | ³»Àå 50MHz ÇÔ¼ö ¹ß»ý±â¸¦ °£ÆíÇÏ°Ô »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. ¿À½Ç·Î½ºÄÚÇÁ¿Í 128K Æ÷ÀÎÆ® ÀÓÀÇ ÆÄÇü ¹ß»ý±â¸¦ ÅëÇÕÇÏ¿© ½ÇÁ¦ ½ÅÈ£¸¦ ¼Õ½±°Ô ĸó, ÆíÁý ¹× Àç»ýÇÒ ¼ö ÀÖ½À´Ï´Ù. |
ÅëÇÕ ·ÎÁ÷ ¾Ö³Î¶óÀÌÀú | 60.6ps±îÁöÀÇ Å¸ÀÌ¹Ö Á¤¹Ðµµ¸¦ ÅëÇØ ¼³°èÀÇ µðÁöÅÐ ºÎºÐÀ» µð¹ö±ëÇÕ´Ï´Ù. ±¤¹üÀ§ÇÑ ½Ã½ºÅÛ °¡½Ã¼ºÀ¸·Î ½Ã½ºÅÛ Å¸ÀÌ¹Ö ¹®Á¦¸¦ ÃßÀûÇÕ´Ï´Ù. |
½Ã¸®¾ó ¹ö½º Æ®¸®°Å¸µ ¹× ºÐ¼® | ÃÖ´ë ¼¼ °³ÀÇ ½Ã¸®¾ó ¹ö½º¿¡¼ Æ®¸®°Å¸µ°ú µðÄÚµùÀ» ÇÑ ¹ø¿¡ ÀÚµ¿ÈÇÕ´Ï´Ù. °ü½É À̺¥Æ®¸¦ ÆľÇÇÏ´Â ½Ã°£À» Àý¾àÇÏ°í ¼öµ¿ ¹ø¿ª ºñÆ®¸¦ ¹æÁöÇÕ´Ï´Ù. |
ÅëÇÕ µðÁöÅÐ Àü¾Ð°è ¹× ÁÖÆļö Ä«¿îÅÍ | Á¦Ç°À» µî·ÏÇϸé, DC Àü¾Ð, AC+DC RMS, AC RMS ¹× ÁÖÆļö¸¦ ½Å¼ÓÇÏ°Ô ÃøÁ¤ÇÒ ¼ö ÀÖ´Â ¿É¼ÇÀ» ¹«·á·Î Á¦°øÇÕ´Ï´Ù. |
¾÷±×·¹ÀÌµå °¡´É¼º | ¾Æ³¯·Î±× ´ë¿ªÆø, ½ºÆåÆ®·³ ºÐ¼®±â, ÀÓÀÇ ÇÔ¼ö ¹ß»ý±â, µðÁöÅРä³Î(MSO), ½Ã¸®¾ó Æ®¸®°Å ¹× ºÐ¼® ÆÐÅ°Áö µîÀ» ¾÷±×·¹À̵åÇÒ ¼ö ÀÖÀ¸¹Ç·Î ÇâÈÄ º¯È¿¡ ÀûÀýÇÏ°Ô ´ëóÇÒ ¼ö ÀÖ½À´Ï´Ù. |
All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise.
MDO4024C | MDO4034C | MDO4054C | MDO4104C | |
---|---|---|---|---|
Analog channels | 4 | 4 | 4 | 4 |
Analog channel bandwidth | 200 MHz | 350 MHz | 500 MHz | 1 GHz |
Rise time | 1.75 ns | 1 ns | 700 ps | 350 ps |
Sample rate (1 ch) | 2.5 GS/s | 2.5 GS/s | 2.5 GS/s | 5 GS/s |
Sample rate (2 ch) | 2.5 GS/s | 2.5 GS/s | 2.5 GS/s | 5 GS/s |
Sample rate (4 ch) Without option SA3 or SA6 With option SA3 or SA6 | 2.5 GS/s 2.5 GS/s | 2.5 GS/s 2.5 GS/s | 2.5 GS/s 2.5 GS/s | 5 GS/s 2.5 GS/s |
Record length (1 ch) | 20 M | 20 M | 20 M | 20 M |
Record length (2 ch) | 20 M | 20 M | 20 M | 20 M |
Record length (4 ch) | 20 M | 20 M | 20 M | 20 M |
Digital channels with MDO4MSO option | 16 | 16 | 16 | 16 |
Arbitrary Function Generator outputs with MDO4AFG option | 1 | 1 | 1 | 1 |
Spectrum analyzer channels with option SA3 or SA6 | 1 | 1 | 1 | 1 |
Spectrum analyzer frequency range | ||||
With Option SA3 With Option SA6 | 9 kHz - 3 GHz 9 kHz - 6 GHz | 9 kHz - 3 GHz 9 kHz - 6 GHz | 9 kHz - 3 GHz 9 kHz - 6 GHz | 9 kHz - 3 GHz 9 kHz - 6 GHz |
¡¾3.0% for variable gain, derated 0.10%/¡ÆC above 30 ¡ÆC
Vertical scale setting | 50 ¥Ø, RMS | ||
---|---|---|---|
MDO4104C (all configurations) | MDO40x4C (with option SA3 or SA6) | MDO40x4C (without option SA3 or SA6) | |
1 mV/div | 0.093 mV | 0.084 mV | 0.163 mV |
100 mV/div | 3.31 mV | 2.37 mV | 2.01 mV |
1 V/div | 24.27 mV | 20.62 mV | 20.51 mV |
Volts/div setting | Offset range | |
---|---|---|
1 M ¥Ø input | 50 ¥Ø input | |
1 mV/div to 50 mV/div | ¡¾1 V | ¡¾1 V |
50.5 mV/div to 99.5 mV/div | ¡¾0.5 V | ¡¾0.5 V |
100 mV/div to 500 mV/div | ¡¾10 V | ¡¾10 V |
505 mV/div to 995 mV/div | ¡¾5 V | ¡¾5 V |
1 V/div to 10 V/div | ¡¾100 V | ¡¾5 V |
5.05 V/div to 10 V/div | ¡¾50 V | NA |
Setup and hold trigger type | Description |
---|---|
Setup Time Range | -0.5 ns to 1.024 ms |
Hold Time Range | 1.0 ns to 1.024 ms |
Setup + Hold Time Range | 0.5 ns to 2.048 ms |
Custom bi-level and tri-level sync video standards.
Custom bi-level and tri-level sync video standards.
1¡Ã350 MHz bandwidth models are recommended for mask testing on telecomm standards >55 Mb/s. 1 GHz bandwidth models are recommended for mask testing on high-speed (HS) USB.
Mask test: Any Ch1 - Ch4
Limit test vertical tolerance from 0 to 1 division in 1 m division increments; Limit test horizontal tolerance from 0 to 500 m division in 1 m division increments
Load standard mask from internal memory
Load custom mask from text file with up to 8 segments
Lock to Source OFF (mask does not re-scale with source-channel settings changes)
Minimum elapsed time (from 1 second to 48 hours and Infinity)
1 kHz - 3 GHz (models with option SA3) or 1 kHz - 6 GHz (models with option SA6)
Span adjustable in a 1-2-5 sequence
Variable resolution = 1% of the next span setting
The resolution bandwidth range for windowing functions is as follows:
Kaiser (default): 20 Hz - 200 MHz
Rectangular: 10 Hz - 200 MHz
Hamming: 10 Hz - 200 MHz
Hanning: 10 Hz - 200 MHz
Blackman-Harris: 20 Hz - 200 MHz
Flat-top: 30 Hz - 200 MHz
Adjusted in a 1-2-3-5 sequence
Vertical setting of 1 dB/div to 20 dB/div in a 1-2-5 sequence
Frequency range | DANL |
---|---|
9 kHz - 50 kHz | < -116 dBm/Hz (< -123 dBm/Hz, typical) |
50 kHz – 5 MHz | < -130 dBm/Hz (< -141 dBm/Hz, typical) |