AC A | 0 - 600.0A ¡¾2.0%rdg¡¾5dgt (50/60Hz) ¡¾3.5%rdg¡¾5dgt (40 - 500Hz) |
---|---|
DC A | 0 - 600.0A ¡¾1.5%rdg¡¾5dgt |
AC V | 6/60/600V Auto Ranging ¡¾1.5%rdg¡¾4dgt (50/60Hz) ¡¾3.5%rdg¡¾5dgt (40 - 400Hz) |
DC V | 600m/6/60/600V Auto Ranging ¡¾1.0%rdg¡¾3dgt |
¥Ø | 600/6k/60k/600k/6M/60M¥Ø (Auto Ranging) ¡¾1%rdg¡¾5dgt (600 - 6M) / ¡¾5%rdg¡¾8dgt (60M) |
Continuity buzzer | Buzzer Sounds at 100¥Ø |
Temperature | -50¨¬C - +300¨¬C (With the use of Temperature probe 8216) |
Frequency/DUTY | 10/100/1k/10kHz (Auto Ranging) / 0.1 - 99.9% |
Conductor size | ¨ª33mm |
Safety Standard | IEC 61010-1 CAT IV 600V, IEC 61010-031, IEC 61010-2-032, IEC 61326 |
Power source | R03 (1.5V) (AAA) ¡¿ 2 |
Dimensions | 243(L) ¡¿ 77(W) ¡¿ 36(D)mm |
Weight | 300g |
Included Accessories | 7066A (Test leads) 9094 (Carrying case) Instruction Manual |
Optional Accessories | 8008 (Multi-Tran) 8216 (Temperature probe) |
AC/DC Digital Clamp Meters
KEW 2055
AC A | 0 - 600.0/1000A ¡¾1.5%rdg¡¾5dgt (50/60Hz) ¡¾3.0%rdg¡¾5dgt (40 - 400Hz) |
---|---|
DC A | 0 - 600.0/1000A ¡¾1.5%rdg¡¾5dgt |
AC V | 6/60/600V Auto Ranging ¡¾1.3%rdg¡¾4dgt (50/60Hz) ¡¾3.0%rdg¡¾5dgt (40 - 400Hz) |
DC V | 600m/6/60/600V Auto Ranging ¡¾1.0%rdg¡¾3dgt |
¥Ø | 600/6k/60k/600k/6M/60M¥Ø (Auto Ranging) ¡¾1%rdg¡¾5dgt (600 - 6M) / ¡¾5%rdg¡¾8dgt (60M) |
Continuity buzzer | Buzzer Sounds at 100¥Ø |
Frequency/DUTY | 10/100/1k/10kHz (Auto Ranging) / 0.1 - 99.9% |
Conductor size | ¨ª40mm |
Safety Standard | IEC 61010-1 CAT IV 600V, IEC 61010-031, IEC 61010-2-032, IEC 61326 |
Power source | R03 (1.5V) (AAA) ¡¿ 2 |
Dimensions | 254(L) ¡¿ 82(W) ¡¿ 36(D)mm |
Weight | 310g |
Included Accessories | 7066A (Test leads) 9094 (Carrying case) Instruction Manual |
Optional Accessories | 8008 (Multi-Tran) |
AC A | 0 - 600.0/1000A ¡¾2.0%rdg¡¾5dgt (50/60Hz) ¡¾3.5%rdg¡¾5dgt (40 - 500Hz) |
---|---|
DC A | 0 - 600.0/1000A ¡¾1.5%rdg¡¾5dgt |
AC V | 6/60/600V Auto Ranging ¡¾1.5%rdg¡¾4dgt (50/60Hz) ¡¾3.5%rdg¡¾5dgt (40 - 400Hz) |
DC V | 600m/6/60/600V Auto Ranging ¡¾1.0%rdg¡¾3dgt |
¥Ø | 600/6k/60k/600k/6M/60M¥Ø (Auto Ranging) ¡¾1%rdg¡¾5dgt (600 - 6M) / ¡¾5%rdg¡¾8dgt (60M) |
Continuity buzzer | Buzzer Sounds at 100¥Ø |
Temperature | -50¨¬C - +300¨¬C (With the use of Temperature probe 8216) |
Frequency/DUTY | 10/100/1k/10kHz (Auto Ranging) / 0.1 - 99.9% |
Conductor size | ¨ª40mm |
Safety Standard | IEC 61010-1 CAT IV 600V, IEC 61010-031, IEC 61010-2-032, IEC 61326 |
Power source | R03 (1.5V) (AAA) ¡¿ 2 |
Dimensions | 254(L) ¡¿ 82(W) ¡¿ 36(D)mm |
Weight | 310g |
Included Accessories | 7066A (Test leads) 9094 (Carrying case) Instruction Manual |
Optional Accessories | 8008 (Multi-Tran) 8216 (Temperature probe) |